GPM from your fixtures, temperature rise from your groundwater, then gas BTU or electric kW, amps and breakers.
Turn these numbers into a build plan.
Your home needs about 6.5 GPM at a 70F rise: a pair of 199k BTU gas units.
How we got this: output BTU = GPM x rise x 500, input = output / 0.95efficiency; electric kW = GPM x rise / 6.83. Every unit is rated at a specific rise, so check the maker's flow chart at 70F, not the headline GPM.
Scale is what kills tankless heaters early. A yearly flush through the isolation valves keeps the warranty and the flow rate.
The calendar file repeats every year. In Blueprint the descale becomes a recurring maintenance task next to the heater's model and install date.
Save this as a Water Heater Replacement project in Blueprint for a plan with permit and venting checks and a parts list sized to this result. Going electric? Check the panel with the electrical load calculator first.
Finished the tankless water heater size? Snap a before and after. The photo maker lines them up into one image you can post, and a free Blueprint account keeps the photos with your measurements and materials.
Your fixtures can pull 6.5 GPM at once, so plan for a 2 x 199k BTU gas (cascaded) unit that delivers 6.5 GPM at a 70F rise (239,474 BTU/hr input). You size, prep and coordinate; a licensed plumber handles gas, venting and electrical under a permit.
Confirm your sizing
Measure cold-water temperature at a tap in winter; your plan assumes 50F in and 120F out. Count what really runs at once: 2 standard showers, 1 kitchen sink, for 6.5 GPM peak.
Check the gas, power and vent path
A 239,474 BTU/hr unit often needs a bigger gas line and meter than a tank heater. Photograph the meter, the gas line size at the old heater, the electrical panel and the wall where a vent could exit. A licensed plumber or gas fitter must assess gas sizing; do not alter gas lines yourself.
Pick the unit
Shortlist condensing models that deliver 6.5 GPM at a 70F rise on the maker's flow chart. Your load is above what one residential unit delivers, so ask about two cascaded units. Note the vent type (PVC for condensing) and whether it needs a 120V outlet.
8 steps · 7 tools · 5 materials
5 more steps, the full tool list and a shopping list you can check off as you go.

Your plan is 60% built. Save it.
3/5Tankless water heater swap, 6.5 GPM
Finished in 2 weekends · $3,125 DIY
Built for your peak demand of 6.5 GPM. Your first plan saves free. No card needed.
Or save it with just your email
We send a link; open it and this plan is your first project. Your first plan saves free. No card needed.
Worked example, a family of 4 running two showers and the kitchen sink (6.5 GPM): in Minneapolis winter water is about 37F, a 83F rise, so the unit needs 269,750 BTU of output and 283,947 BTU of input at 95% efficiency. In Miami the water is about 66F, a 54F rise, and 184,737 BTU of input is enough.
| Unit | 35F rise | 45F rise | 55F rise | 65F rise | 75F rise |
|---|---|---|---|---|---|
| 120k BTU gas | 6.5 | 5.1 | 4.1 | 3.5 | 3 |
| 160k BTU gas | 8.7 | 6.8 | 5.5 | 4.7 | 4.1 |
| 180k BTU gas | 9.8 | 7.6 | 6.2 | 5.3 | 4.6 |
| 199k BTU gas | 10.8 | 8.4 | 6.9 | 5.8 | 5 |
| 18 kW electric | 3.5 | 2.7 | 2.2 | 1.9 | 1.6 |
| 27 kW electric | 5.3 | 4.1 | 3.4 | 2.8 | 2.5 |
| 36 kW electric | 7 | 5.5 | 4.5 | 3.8 | 3.3 |
| Fixture | GPM |
|---|---|
| Low-flow shower | 1.8 |
| Standard shower | 2.5 |
| Bathtub | 4 |
| Kitchen sink | 1.5 |
| Bathroom sink | 0.5 |
| Dishwasher | 1.2 |
| Clothes washer | 1.8 |
| State | Groundwater |
|---|---|
| Minnesota | 45F |
| North Dakota | 43F |
| Maine | 45F |
| Michigan | 47F |
| New York | 48F |
| Massachusetts | 49F |
| Washington | 50F |
| Colorado | 50F |
| Ohio | 52F |
| Pennsylvania | 52F |
| Illinois | 54F |
| Missouri | 57F |
| Virginia | 57F |
| North Carolina | 60F |
| California | 60F |
| Georgia | 64F |
| Arizona | 68F |
| Texas | 70F |
| Louisiana | 70F |
| Florida | 74F |
Gas units reach 199,000 BTU, enough for two or three fixtures in a cold climate, but need a gas line sized for that load and a PVC vent (condensing) or stainless vent (non-condensing). Electric units need no vent but draw 75 to 150 A, so they suit warm climates, small homes or point-of-use. Check the panel with the electrical load calculator, and follow the water heater installation cheat sheet and the permit and inspection guide.
Water goes lukewarm when a second shower or the dishwasher starts, temperature swings in winter but not summer, or the unit cycles off at low flow. The fix is a bigger unit, a second unit in cascade, or low-flow (1.8 GPM) shower heads that cut demand by a quarter.
Calculate residential electrical service requirements using NEC methods
Calculate ROI and payback period for energy efficiency upgrades
Tank size by bedrooms, existing tank volume, drain field area by soil and your pumping schedule
Pipe sizes, fittings, codes, soldering techniques, and common repairs
Reference table showing maximum flow rate and recommended pipe size for PEX tubing
Reference sheet detailing gauge measurements and calibration procedures for PEX tools