Find the right duct size for any room from CFM, friction rate, or velocity
Turn these numbers into a build plan.
Running a line set too? See the refrigerant line calculator. Wrap ducts in unconditioned space with the insulation calculator, and check the permit and inspection cheat sheet before changing a system.
Finished the ductwork sizing? Snap a before and after. The photo maker lines them up into one image you can post, and a free Blueprint account keeps the photos with your measurements and materials.
A 8" round supply run sized for 200 CFM, which moves air at about 573 FPM (quiet). Planned for a typical 20 ft run from the trunk to one register; anything touching the furnace, refrigerant or gas belongs to a licensed HVAC tech.
Shut off the system and check scope
Turn the thermostat off and kill power to the air handler at its switch. This plan covers duct between the trunk and the register only. Furnace, coil, refrigerant, gas and electrical work belong to a licensed HVAC tech, and many areas need a mechanical permit for new runs.
Plan the route
Map the shortest path with the fewest turns from the trunk to the register. Each elbow adds resistance, so 8" round sized for 200 CFM only works if the run stays short and smooth.
Cut in the takeoff
Trace the takeoff on the trunk, drill a starter hole, cut with snips, then bend the tabs over and screw it in place. Set the damper fully open for now.
8 steps · 8 tools · 8 materials
5 more steps, the full tool list and a shopping list you can check off as you go.

Your plan is 60% built. Save it.
3/5Supply duct run, 8" round
Finished in 1 weekend · $194 DIY
Built for your airflow of 200 CFM. Your first plan saves free. No card needed.
Or save it with just your email
We send a link; open it and this plan is your first project. Your first plan saves free. No card needed.
| Round size | Metal | Flex | Rectangular equivalent |
|---|---|---|---|
| 4 in | 33 | 26 | 4 x 4, 6 x 6, 8 x 8 |
| 5 in | 59 | 48 | 6 x 4, 6 x 6, 8 x 8 |
| 6 in | 96 | 78 | 8 x 4, 6 x 6, 8 x 8 |
| 7 in | 145 | 117 | 12 x 4, 8 x 6, 8 x 8 |
| 8 in | 206 | 166 | 16 x 4, 10 x 6, 8 x 8 |
| 9 in | 281 | 227 | 20 x 4, 12 x 6, 10 x 8 |
| 10 in | 372 | 300 | 26 x 4, 16 x 6, 12 x 8 |
| 12 in | 549 | 487 | 40 x 4, 24 x 6, 16 x 8 |
| 14 in | 748 | 732 | 60 x 4, 34 x 6, 22 x 8 |
| Fitting | Equivalent length |
|---|---|
| Smooth 90° elbow | 15 ft |
| Trunk takeoff | 35 ft |
| Register boot | 35 ft |
| Run | Airflow | Size | Velocity | Run pressure drop |
|---|---|---|---|---|
| Bedroom, 20 ft metal, 1 elbow | 120 CFM | 7 in | 449 FPM | 0.059 in |
| Bonus room addition, 35 ft flex, 2 elbows | 300 CFM | 10 in | 550 FPM | 0.107 in |
| Bath exhaust fan, 15 ft flex | 80 CFM | 7 in | 299 FPM | 0.012 in |
Bath fans are rated at 0.1 in or 0.25 in of static pressure; size the duct so the run stays under the fan's rating.
One added branch is a reasonable DIY job. Replacing a system, adding a zone, or finishing a basement with several new runs needs a Manual J load and a Manual D duct design so every room gets its air and the blower is not starved. Check the permit and inspection cheat sheet, pick filters with the MERV filter cheat sheet, and see the refrigerant line calculator for split systems.
Liquid and suction line sizes, extra charge per foot and a chart for R-410A, R-32 and R-454B
Rough BTU, tonnage and heat-loss estimate to check a contractor's sizing
Rolls, bags, depth and cost for attics, walls and floors, matched to your climate zone
Chart explaining MERV scale and correlating ratings to air quality function
Max length calculator (35 ft minus elbows), 8 install steps, wall vs roof vs soffit, approved duct, clearances, cleaning and FAQ
Wire gauges, circuit breaker sizes, electrical codes, and safety guidelines